CMS products provide a DIY 240V wiring solution for your RV.
This connecting cable links CMS J-Series 240V soft-wiring components. It comes in various lengths as shown in the title. J-Series and C-Series use different connectors and do not connect directly.
Each cable has a female and male end so they cannot be connected incorrectly. Each connection has a security clip that can only be separated by manual manipulation; they will never come adrift within the wall provided they are pushed tight until the clip engages.
The rating of the cables exceeds the 15amp supply provided to RVs. The number of cables and power points should be limited to either 10 double power points or 12 single power points per circuit, with fewer points where expected loads require it. For example, an electric stove would reduce this number. The cable's 20 A rating does not increase the available supply or circuit capacity.
Cables should be longer than the distance between power points. As a general rule allow 300mm extra, but even more will not harm. Remember the cables clip in facing down from the power point within the wall, so branching off to a power point above will require curving the cable back up.
Cables can be joined using a CMS double adapter. See dimensions of double adapters. Each cable end has a cross section of 25 mm x 16 mm.
The RV wiring system also needs circuit protection and a chassis earth connection. Overcurrent protection and residual-current protection perform different functions: a circuit breaker alone does not provide residual-current protection, and an RCD without integral overcurrent protection does not replace a circuit breaker.
Cables should not be placed near any sharp edges which may damage the outer sheath. Outlet locations must maintain the required separation from showers and baths. Ensure all cable connections are fully engaged and their security clips are locked before completing cladding.
If running power below floor to the other side of the RV it must be enclosed within the chassis or conduit.