Replacement blower motor assembly for the Girard GSWH-2 instant hot water system. The blower supplies the airflow needed for combustion.
An E5 error means the heater has not detected the motor signal before ignition or during operation. A wiring fault at the motor connections can also cause E5, so the code alone does not confirm that the blower assembly needs replacing.