PDF Product Manual (559kb)
Below is a summary of the contents of this PDF. You can also view or save the original full PDF. The products that this PDF relate to are listed at the bottom.
MAXXFAN Dome Installation and Operation Guide
Models 3810, 3812
Technical Specifications and Installation Instructions
Installation Requirements:
- Roof Opening: Requires a minimum 6 1/4 inch diameter.
- Roof Thickness: Suitable for a minimum of 1 inch to a maximum of 6 inches.
- Electrical Requirements: Minimum 12 Volt DC, 2 amp service. Ensure the circuit is fused and uses appropriate gauge stranded wire for connections.
Safety Precautions:
- Use as intended by AIRXCEL, INC.
- Before servicing or cleaning, switch power off and lock the service disconnecting means to prevent accidental power on.
- For general ventilation only. Do not use to exhaust hazardous or explosive materials and vapors.
Installation Steps:
Prepare Roof Opening:
- Remove old vent and sealant around the opening.
- Apply BUTYL tape or equivalent to the underside of the flange in the provided groove.
Install the Fan:
- Orient the fan with the button toward the front of the coach.
- Ensure wires are hanging inside the coach.
- Center the fan in the opening and secure with eight screws provided at each dimple location on the flange.
- Apply sealant around the perimeter of the flange and over screw heads.
Adjust Sleeve Length (if necessary):
- For roofs thicker than 1 inch, use the extension sleeve.
- Measure the distance from the vehicle ceiling to the base of the fan and cut the sleeve accordingly.
- For roofs 1 inch thick, the sleeve is not used. For roofs 6 inches thick, use the full-length sleeve.
Wire Connections:
- For non-LED models, connect the 12VDC supply wires to the fan wires as marked.
- For LED models, also connect the LED light wires as marked.
- Secure the garnish ring to the ceiling with provided screws.
Operating Instructions:
- To Open/Close Lid: Push the button on the handle to disengage the clip and slide the handle up or down to open or close the lid.
- Fan Operation: Push the ON/OFF button on the fan to activate the exhaust fan.
- LED Lighting (if applicable): Operated by the push button on the garnish ring. The LED lighting and fan operate independently.
Maintenance:
- Clean with mild soap and water only.
- The screen can be removed for cleaning by unscrewing the four screws. Do not operate the fan with the screen removed.
- The fan has a 5 amp fuse. To replace, turn the fuse cap to the left, replace with a 5 amp, type GMA fast-acting fuse, and secure the cap.
Troubleshooting and Warranty:
For operational issues or warranty information, contact AIRXCEL / MAXXAIR VENTILATION SOLUTIONS Customer Service.
This guide is intended for customer service and technical staff to assist in the installation, operation, and troubleshooting of the MAXXFAN Dome models 3810 and 3812. Ensure all safety precautions are followed and refer to this document for detailed instructions.