PDF Product Manual
Below is a summary of the contents of this PDF. You can also view or save the original full PDF. The products that this PDF relate to are listed at the bottom.
HB9000 Plus Heat Pump Technical and Customer Service Manual
Safety Precautions
- Children and Vulnerable Individuals: This appliance can be operated by children aged 8 years and above and individuals with reduced physical, sensory, or mental capabilities with supervision. Children should not perform cleaning or maintenance.
- Supply Cord: If damaged, it must be replaced by qualified personnel to avoid hazards.
- Disconnection Switch: Ensure a full disconnection switch is installed in the fixed wiring as per wiring rules.
Product Overview
Machine Description
The HB9000 Plus is a versatile heat pump designed for efficient heating and cooling with a variety of modes including night mode, fan speed adjustments, and a dehumidification feature. It does not support clock setting or lock airflow direction functions.
Controls and Operation
- Wall Pad: Includes signal receiver, ON/OFF button, MODE selection (cooling/heating), Wifi connectivity for app control, FAN speed selection, and temperature adjustment (UP/DOWN buttons).
- Modes: Features cold mode, auto fan, automatic mode, fan mode, heat pump mode, sleep timer, and temperature selection.
- Sleep Mode: Activated by pressing the sleep mode button.
Installation
- Placement: Choose a location that allows for optimal performance. Keep a distance between the unit and surrounding walls as specified in the installation guide.
- Fixing and Grille Installation: Open the side cover, stick foam around the air inlet, make a hole of the indicated size, fix the grille, and install the unit.
- Wall Pad Installation: Requires a 20mm hole for the cable, use wooden screws for support, connect the extension cable, and place the wall pad in its support.
- Air Ducting: Use trade parts not supplied, recommended to use cardboard pipe with an aluminium core and PVC covering, 60mm inside nominal diameter. Ensure air pipes are short, straight, and not longer than 5m.
Technical Specifications
- Dimensions: Various dimensions provided for installation and fixing holes.
- Power: 2650W cooling, 2700+500W heating.
- Voltage: 230V - 50Hz.
Routine Maintenance and Troubleshooting
- Troubleshooting: Refer to the trouble, causes, and remedies section for common issues and solutions.
- Maintenance: Special maintenance steps are outlined for optimal performance.
Wiring and Spare Parts
- Wiring Diagram: Detailed wiring for the compressor, fan motor, heater, and control connections.
- Spare Parts Catalogue: Includes remote control, batteries, grille, air pipes, compressor, condenser, evaporator assembly, PCB, wall pad controller, sensors, and more.
Decommissioning and Recycling
Follow the guidelines for safely decommissioning the unit and recycling its components.
This manual serves as a comprehensive guide for customer service and technical staff to assist with product inquiries, troubleshooting, and maintenance of the HB9000 Plus Heat Pump.