Dometic RMD 10.5XS Refrigerator Installation and Operation Manual for Customer Service and Technical Staff
1. Explanation of Symbols:
- !WARNING! Indicates a hazardous situation that could result in death or serious injury.
- !CAUTION! Indicates a hazardous situation that could result in minor or moderate injury.
- !NOTICE! Indicates a situation that could result in property damage.
- !NOTE! Provides supplementary information for operating the product.
2. Safety Instructions:
- The manufacturer is not liable for damages due to faulty assembly/connection, mechanical influences, incorrect voltage, or unauthorized alterations.
- Electrical installations must comply with AS/NZS 3001.
- Gas installations must comply with AS/NZS 5601.2.
- Do not open the absorber unit; it is under high pressure.
- Ensure clean handling if using silicone sealant to avoid fire risks.
- Do not operate the refrigerator if visibly damaged.
- Use only universal LPG gas and operate at the pressure shown on the type plate.
- For disposal, dismantle all doors and leave shelves in to prevent accidental enclosure.
3. Scope of Delivery:
- 1 Refrigerator
- 1 Drain hose
- 1 Sealing strip
- Installation, Operating Manual, and Quick Start Guide
4. Accessories (Not Included):
- Dometic gas flue kit 3776
- Dometic Roof Vent Kit
- LS 300 ventilation grille
5. Intended Use:
- Suitable for installation in caravans and motor homes.
- Not suitable for storing medications, corrosive substances, or freezing previously unfrozen food.
6. Installation Instructions:
- Install the refrigerator in a draft-proof location.
- Ensure the refrigerator does not exceed an angle of 3 degrees.
- Maintain a minimum clearance of 10 mm and a maximum of 25 mm between the refrigerator and rear wall.
- Use original Dometic ventilation grills for safe operation.
- Ensure proper ventilation by installing air inlet and outlet vents.
- Install a separate flue duct under the air outlet vent.
- Secure the refrigerator by fastening it through built-in bushes to avoid instability.
7. Connecting the Refrigerator:
- Gas Connection: Must be performed by a specialist. Use a metal-sealed screw connection and ensure the gas filter is not removed.
- Electrical Connection: Can be connected to both DC and AC power supplies. Ensure the mains socket is accessible and the connection cables do not contact hot or sharp parts.
- DC Power: Protect the supply line to the heating element with a 20 A fuse and the electronics with a 2 A fuse. Use recommended cable sizes for connections.
8. Technical Data:
- Total volume: 173 liters
- Fridge volume: 140 liters
- Freezer volume: 33 liters
- Connection voltage: 230 - 240 V / 50 - 60 Hz or 12 V
- Power input: 250 W (240 V), 170 W (12 V)
- Power consumption: 5.0 kWh/24 h (240 V)
- Gas consumption: 586 g/24 h
- Dimensions (WxHxD): 526 x 1246 x 615 mm (without flange), 550 x 1260 x 615 mm (with flange)
- Weight: 52.5 kg
Note: This manual is intended to provide comprehensive information to support customer service and technical staff in the installation, operation, and troubleshooting of the Dometic RMD 10.5XS refrigerator. Ensure all installations and operations comply with the specified safety standards and regulations.