MAXXFAN® Deluxe Customer Service and Technical Support Guide
Installation Overview
Roof Opening Requirements
- KI Models: Require a standard RV roof opening of 355mm x 355mm.
- KI40 Models: Require a roof opening of 400mm x 400mm.
Roof Area and Thickness
- Ensure a clear roof area of at least 203mm to the rear for exhaust/intake louvers.
- Designed for roof thickness from 25mm to a maximum of 90mm. For roofs thinner than 25mm, build additional thickness using suitable materials. Longer Garnish Rings are available for thicker roofs.
Electrical Requirements
Designed for a nominal 12V DC system with a minimum circuit capacity of 5 amps. Use the proper gauge stranded wire for connections.
Installation Steps
- Preparing the Roof Opening:
- Remove old vent and sealant around the opening.
- Place the Roof Receiving Flange in the opening, trace around it, and ensure it's centered.
- Applying Sealant:
- Use compatible caulking/sealant (avoid solvents like Xylene, Toluene, etc., and Polysulfide type sealants). Silicone Sealants like G.E. Silicone II are recommended.
- Electrical Connection:
- Connect the vehicle’s 12V power to the MAXXFAN power wires, ensuring correct polarity.
- Mounting the MAXXFAN:
- Confirm metal mounting clips are in place. Lower the MAXXFAN onto the Roof Receiving Flange, ensuring wires are not entangled.
- Securing the MAXXFAN:
- Use the provided 19mm #10 stainless steel screws to fasten the MAXXFAN to the Roof Receiving Flange. Apply additional sealant over screw heads and flange edges.
- Trimming the Garnish Ring:
- Measure the distance from the ceiling surface to the Control Plate at each corner, add 6mm to 12.5mm to each measurement, mark, and trim the Garnish Ring accordingly.
- Finalizing Installation:
- Place excess wiring inside the roof opening, slide the Garnish Ring into position, and secure with provided screws.
Operating Instructions
Manual Models
- Vent Lid Operation: Pull the knob to unlock before turning. Rotate clockwise to close and counter-clockwise to open. Push in to lock.
Automatic Models
- Vent Lid Operation: Rotate the knob without pushing or pulling. Clockwise to close, counter-clockwise to open.
Keypad Controls
- ON/OFF: Starts or stops the fan. In automatic models, also opens/closes the lid.
- IN/OUT: Reverses fan direction. Pauses before changing direction.
- AUTO: Engages Auto Mode, allowing the thermostat to control the fan based on set temperature.
- Arrow Keys: Adjust thermostat temperature or fan speed. Pressing both simultaneously on automatic lift models opens/closes the lid.
Remote Control (7000KI, 7500KI, 7000KI40, 7500KI40 Models)
Controls include fan on/off, vent lid position, air exhaust/intake direction, auto mode, thermostat set temperature, and fan speed adjustment.
Maintenance and Warranty
- Cleaning: Use only mild soap and water. Avoid petroleum-based or solvent-based cleaners.
- 1-Year Limited Warranty: Covers manufacturing defects for 1 year from the purchase date. Does not cover labor, freight costs, or damages from misuse or improper installation.
Troubleshooting
- No Power/Operation: Check 12V DC connections and ensure the circuit can supply a minimum of 5 amps. Reset the self-resetting fuse by removing and re-applying power.
- Improper Vent Operation: Ensure the knob is correctly operated for manual models and check remote control batteries for automatic models.
For further assistance, refer to the specific model's operating guide or contact technical support.