PDF Installation Manual (2MB) Thetford N314E 3-Way Fridge & Freezer - 93 Litre (521w x 756h)

# Australian Refrigerator Models Installation and Troubleshooting Guide

## For Customer Service and Technical Staff

### Models Covered:
- N314E.3F (93 liters, 3-way operation: LP gas, 240V AC, 12V DC)
- N414E.3F (128 liters, 3-way operation)
- N514E.3F (164 liters, 3-way operation)

### Safety Precautions
- **WARNING:** Improper installation or maintenance can cause injury or damage. Ensure proper ventilation to avoid lethal fumes.
- **Gas Safety:** If you smell gas, open windows, don't touch electrical switches, extinguish flames, and call your gas supplier.
- **Installation Restrictions:** Not for below deck marine or fixed indoor cabin applications. Must use Thetford designed ventilation.

### Installation Requirements
- **Certification:** Complies with Australian Gas Association Standard AS4555/AG105 and AS/NZS 3350.1:1994.
- **Ventilation:** Must have one lower intake vent and one upper exhaust vent. Ensure clearances for proper air flow: 0 mm min to 25 mm max around the unit.
- **Enclosure Dimensions:**
- N314E.3F: 756mm H x 521mm W x 543mm D
- N414E.3F: 929mm H x 602mm W x 620mm D
- N514E.3F: 1083mm H x 602mm W x 620mm D

### Installation Steps
1. **Vent Installation:** Follow the manual for specific vent part numbers and installation instructions.
2. **Refrigerator Placement:** Ensure a complete combustion seal around the mounting flanges.
3. **Door Panel Installation:** Decorative panels must be ≤5mm thick. Sizes vary by model.
4. **Door Swing Reversal:** Hinges allow for the door to open from the opposite side.
5. **Travel Latch Adjustment:** Can be positioned at the top or bottom of the door.

### Electrical Connection
- **AC Operation:** 240V AC, 0.7-1.0 Amps depending on the model.
- **DC Operation:** 12V DC, 11.5-15.6 Amps depending on the model.
- **Safety:** Ensure proper grounding and avoid contact between wiring and hot surfaces.

### LP Gas Connection
- **Pressure:** Operates at 2.7kPa. Usage is 1.00 MJ/h for N314E.3F and 1.40 MJ/h for N414E.3F and N514E.3F.
- **Installation:** Use 3/8 inch copper tubing and a 3/8 inch SAE female flare fitting. Check for leaks with a leak detecting solution.

### Troubleshooting
- **AC, DC, or LP Gas Operation Issues:** Verify connections, settings, and supply levels.
- **Cooling Performance:** Ensure vents are clear, the vehicle is level, and the unit is defrosted.
- **Frost Build-up:** Check for sealed food containers, minimize door openings, and verify door gasket seals.

### Additional Notes
- **Operation Check:** Verify correct operation post-installation as per the Owner’s Manual.